您好,欢迎访问中国农业科学院 机构知识库!

High Resolution X-ray Imaging of Dynamic Solute Transport in Cyclically Deformed Porous Tissue Scaffolds

文献类型: 会议论文

第一作者: Jorn Op Den Buijs

作者: Jorn Op Den Buijs 1 ; Kee-Won Lee 2 ; Steven M. Jorgensen; Shanfeng Wang; Michael J. Yaszemski; Erik L. Ritman;

作者机构: 1.Dept. of Physiology and Biomedical Engineering, Physiological Imaging Research Laboratory,Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA

2.Dept. of Orthopedic Surgery, Tissue Engineering and Polymeric Biomaterials Labora

关键词: scaffold;projection x-ray;tissue engineering;solute transport;dynamic compression

会议名称: Conference on Medical Imaging 2008: Physiology, Function, and Structure from Medical Images; 20080217-19; San Diego,CA(US)

主办单位:

页码: i,x-

摘要: The objective was to develop a method for high-resolution imaging of dynamic solute transport in cyclically deforming porous scaffolds for tissue engineering applications. A flexible cubic scaffold with single cylindrical channel was fabricated from a biodegradable polymer blend using a combined 3D printing and injection molding technique. The scaffold was attached to the bottom of a fluid reservoir mounted underneath a compression apparatus placed inside the X-ray scanner. The scaffold was positioned with the channel axis perpendicular to the X-ray beam. The container was filled with glycerin, and a solution of the contrast agent sodium iodide (Nal) in glycerin was injected into the scaffold channel. Intervals of compression cycles (14.5 ± 2.1 % compression at 1.0 Hz) were applied to the top face of the scaffold. After each interval the compression was temporarily paused to obtain a two-dimensional image at 20 μm pixel resolution. A series of images was also obtained without application of the compression cycles to quantify the effect of passive diffusional removal of NaI from the channel. The average NaI concentration in the channel decreased by 82% after 300 cycles (5 min.) of compression, by 40% after 60 min. of passive removal. Spatial profiles of the NaI concentration along the channel axis indicated that compression-induced transport preferentially removed the contrast agent at the pore openings. We conclude that convective transport induced by cyclic mechanical deformation of artificial tissue scaffolds could significantly contribute to the rate and depth of nutrient transport inside the scaffold, as compared to slow diffusive transport alone.

分类号: [ "R312" , "R312"]

  • 相关文献

[1]A Novel Collagen Sponge for Cartilage Tissue Engineering. Guoping Chen,Daisuke Akahane,Naoki Kawazoe,Yoshio Shirasaki,Junzo Tanaka,Katsuyuki Yamamoto,Tateishi Tateishi. 2007

[2]Fabrication of Macroporous Scaffold Using Calcium Phosphate Glass for Bone Regeneration. T. Yoshikawa1,Y. Ueda1rl Ohmura,Y. Sen1,J. lida,M. Koizumi,K. Kawate. 2003

[3]Evaluation of RGD-grafted Porous PLLA Scaffold for Chondrogenic Differentiation of Stem Cells. Hyun Jung Jung,Kwideok Park,Kyoung Jin Cho,Kwang-Duk Ann,Dong-June Ann,Dong Keun Han. 2007

[4]Comparative study of desktop- and synchrotron radiation-based micro computed tomography analyzing cell-seeded scaffolds in tissue engineering of bone. Adam Papadimitropoulos,Sebastian Friess,Felix Beckmann,Phil Salmon,Stefania Riboldi,Dietmar Hutmacher,Ivan Martin,Bert Muller. 2008

[5]芝麻基因组解析与利用. 王林海. 2014

[6]Enhanced Proliferation and Osteogenic Differentiation of Mesenchymal Stem Cells on Graphene Oxide-Incorporated Electrospun Poly(lactic-co-glycolic acid) Nanofibrous Mats. Luo, Yu,Shen, He,Cao, Yuhua,Huang, Jie,Zhang, Mengxin,Dai, Jianwu,Zhang, Zhijun,Luo, Yu,Shi, Xiangyang,Fang, Yongxiang,Dai, Jianwu,Fang, Yongxiang. 2015

[7]An in situ method to measure the longitudinal and transverse dispersion coefficients of solute transport in soil. Zhang, Xiaoxian,Qi, Xuebin,Zhou, Xinguo,Pang, Hongbin.

[8]The impact of boundary on the fractional advection-dispersion equation for solute transport in soil: Defining the fractional dispersive flux with the Caputo derivatives. Zhang, Xiaoxian,Lv, Mouchao,Crawford, John W.,Young, Iain M..

[9]Global sensitivity analysis and calibration of parameters for a physically-based agro-hydrological model. Xu, Xu,Huang, Guanhua,Xu, Xu,Huang, Guanhua,Sun, Chen,Mohanty, Binayak P.. 2016

[10]Shape Memory Scaffold with a Tunable Recovery Temperature for Filling Critical-Size Bone Defects. R.M. Baker,J.H. Henderson,P.T. Mather. 2013

[11]Apatite Foam Fabrication Based on Hydrothermal Reaction of α-Tricalcium Phosphate Foam. Kunio lshikawa,Satoshi Karashima,Akari Takeuchi,Shigeki Matsuya. 2008

[12]Elastic Ceramic-Polymer Scaffold with Interconnected Pore Structure: Preparation and In Vitro Reactivity. Minna Malin,Joni Korventausta,Ville Meretoja,Jukka Seppaelae. 2008

[13]Two-Photon Polymerization for Microfabrication of Three-Dimensional Scaffolds for Tissue Engineering Application. T. Weiβ,A. Berg,S. Fiedler,G. Hildebrand,R. Schade. 2009

[14]Mechanical Property of Poly (3-hydroxybutyrate)/Bioglass Nanocomposite Scaffolds for Bone Tissue Engineering. H. Hajiali,M. Hosseinalipour,S. Karbasi,H.R. Rezaie. 2010

[15]Preparation of the Hydroxyapatite/Collagen Three-Dimensional Scaffold from Its Membrane. Masanori Kikuchi. 2008

[16]Fabrication of Tailored Hydroxyapatite Scaffolds: Comparison between a Direct and an Indirect Rapid Prototyping Technique. U. Deisinger,S. Hamisch,M. Schumacher,F. Uhl,R. Detsch,G. Ziegler. 2008

[17]Injectable Hydrogel Based on Oxidized Dextran and Amino Gelatin for the Biomedical Application. GENG Xiao-hua,MO Xiu-mei,HE Li-ping,LI Da-wei. 2012

[18]Development of Nano-Matrix Composed of Poly (xi -caprolactone) and Polyethylenimine Using electrospinning system for Tissue engineering. Jang Ho Kim,Ki Taek Lim,InYong Kim,Hyun Mok Son,Hoon Seonwoo,Soo Jung Baik,Pill Hoon Choung,Chong Su Cho,Jong Hoon Chung. 2009

[19]A NOVEL AUTOMATION SYSTEM FOR MICROPLASMA SURFACE PATTERNING AND BIOLOGICS PRINTING. Chengyang Wang,Qudus Hamid,Jessica Snyder,Halim Ayan,Wei Sun. 2013

[20]Nano-apatite/polymer Biocomposite For Tissue Engineering. W. Wei Sr.,C. Chen Sr.,H. Hong Sr.,Y. Yuan Sr.,L. Liu. 2005

作者其他论文 更多>>