您好,欢迎访问中国农业科学院 机构知识库!

Constrained maximum intensity optimized multi-electrode tDCS targeting of human somatosensory network

文献类型: 会议论文

第一作者: Asad Khan

作者: Asad Khan 1 ; Marios Antonakakis 1 ; Nikolas Vogenauer 2 ; Andreas Wollbrink; Sonja Suntrup-Krueger; Till R. Schneider; Christoph S. Herrmann; Michael Nitsche; Walter Paulus; Jens Haueisen; Carsten H. Wolters;

作者机构: 1.Institute for Biomagnetism and Biosignal Analysis, University of Muenster, Münster, Germany

2.Institute for Biomagnetism and Biosignal Analysis, University of Muenst

关键词: Electrodes;Current density;Optimization;Finite element analysis;Brain modeling;Analytical models;Standards

会议名称: Annual International Conference of the IEEE Engineering in Medicine and Biology Society

主办单位:

页码: 5894-5897

摘要: Transcranial direct current stimulation (tDCS) is a noninvasive method that delivers current through the scalp to enhance or suppress brain activity. The standard way of applying tDCS is by the use of two large rectangular sponge electrodes on the scalp. The resulting currents often stimulate a broad region of the brain distributed over brain networks. In order to address this issue, recently, multi-electrode transcranial direct current stimulation with optimized montages has been used to stimulate brain regions of interest (ROI) with improved trade-off between focality and intensity of the electrical current at the target brain region. However, in many cases only the location of target region is considered and not the orientation. Here we emphasize the importance of calculating the individualized target location and orientation by combined electroencephalography and magnetoencephalography (EMEG) source analysis in individualized skull-conductivity calibrated finite element method (FEM) head models and stimulate the target region by four different tDCS montages. We have chosen the generator of the P20/N20 component, located at Brodmann area 3b and oriented mainly from posterior to anterior directions as our target for stimulation because it can be modeled as a single dipole source with a fixed position and orientation. The simulations will deliver optimized excitatory and inhibitory electrode montages that are in future investigations compared to standard and sham tDCS in a somatosensory experiment. We also present a new constrained maximum intensity (CMI) optimization approach that better distributes the currents over multiple electrodes, therefore should lead to less tingling and burning sensations at the skin, and thus allows an easier realization of the sham condition significantly reducing the current intensity parallel to the target.

分类号: q81

  • 相关文献

[1]Improved EEG Decoding Method Based on Spiking Neural Network for SSVEPs’ Classification. Yufan He,Yong Huang,Yan Li,Haoming Chu,Lirong Zheng,Ning Ma,Yuxiang Huan. 2023

[2]Longitudinalgeneticanalysisforgrowthtraitsinthecompletediallelcrossofrainbowtrout. 宋禹昕. 2014

[3]转TGEV-S基因玉米中目的基因的PCR检测及条件优化PCRdetectionofthetargetgeneintransgenicmaizederivedspikeglycoproteingeneofporcinetransmissiblegastroenteritisvirus. 覃湘婕1,2,周宏专2,3,杨兵2,徐福洲2,薛静2,张晓东2,王金洛2*TANXiangjie1,2,ZHOUHongzhuan2,3,YANGBing2,XUFuzhou2,XUEJing2,ZHANGXiaodong2,WANGJinluo2*. 2014

[4]Development of an automatic milk standards packaging system. Li, Y,Ruan, R,Li, J,Yu, Q,Lin, X,Chen, P,Deng, S,Grounli, B. 2005

[5]Finite Element Analysis and Stress Testing for Telescopic Boom of Telehandler. Yan, Hongfeng,Wang, Weiping,Wang, Zhi,Zhang, Hui,An, Xiping,Zhang, Huixian. 2013

[6]Finite Element Analysis for the working device of rough terrain forklift. Yan, Hongfeng,Wang, Weiping,Qi, Xiangyang,Tian, Tian,He, Yue,Zhang, Huixian. 2013

[7]Hip Joint Implant Loading During Routine Activities of Elderly Indonesian. Rilo Berdin Taqriban,Dwi Basuki Wibowo,Ismoyo Haryanto,Rifky Ismail. 2021

[8]FE-analysis of dental implants with sinus lift. P. Schuller-Gotzburg,K. Entacher,A. Petutschnigg,W. Pomwenger,F. Watzinger. 2009

[9]A new protocol to compare successful versus failed patients using the electromyographic diaphragm signal in extubation process. Alejandro Arboleda,Lusvin Amado,Javier Rodriguez,Francisco Naranjo,Beatriz F. Giraldo. 2021

[10]Toward the quantification of adeno-associated virus titer by electrochemical impedance spectroscopy. Junhyeong Wang,Mahshid Hosseini,Shriarjun Shastry,Eduardo Barbieri,Wenning Chu,Stefano Menegatti,Michael A. Daniele. 2023

[11]Cross-Frequency Coupling Features of Postictal Generalized EEG Suppression State. Vasily Grigorovsky,Jose Martin del Campo,Yotin Chinvarun,Peter Carlen,Berj L. Bardakjian. 2019

[12]Live Demonstration: HemeChip - A Portable Microchip Electrophoresis Technology for Point-of-Care Sickle Cell Disease Screening. Muhammad Noman Hasan,Arwa Fraiwan,Umut A. Gurkan,Jane A. Little. 2018

[13]A Novel Scanning Algorithm for MEG/EEG imaging using Covariance Partitioning and Noise Learning. Chang Cai,Kensuke Sekihara,Srikantan S Nagarajan. 2019

[14]EEG Source Analysis with a Convolutional Neural Network and Finite Element Analysis. Thanos Delatolas,Marios Antonakakis,Vangelis Sakkalis,Carsten H. Wolters,Michalis Zervakis. 2023

[15]Cross-subject Drowsiness Recognition Model Based on the Multi-scale Parallel Convolution of EEG Channels. Shaohua Wan,Songquan Li,Rongbo Zhu,Jun Yuan. 2023

[16]Non-contact Apnea-Hypopnea Index Estimation using Near Infrared Video *. Kaiyin Zhu,Azadeh Yadollahi,Babak Taati. 2019

[17]Quality Supervision of Large and Complex Aerospace Engineering Projects. Bo Duan,Gang Wu,Mingfang Dong,Yu Liu. 2023

[18]Analysis of Quality Inspection and Reliability Evaluation Methods for TSV Silicon Interposers. Yingying Liu,Yu Fu,Likang Zhang,Zhihui Wang,Ke Shi,Pei Liu,Zhipeng Mei. 2023

[19]Evaluation of a QT Adaptation Time Estimator for ECG Exercise Stress Test in Controlled Simulation. Cristina Pérez,Esther Pueyo,Juan Pablo Martínez,Leif S?rnmo,Pablo Laguna. 2023

[20]Sleep Apnea Severity Estimation from Respiratory Related Movements Using Deep Learning. Maziar Hafezi,Nasim Montazeri,Kaiyin Zhu,Hisham Alshaer,Azadeh Yadollahi,Babak Taati. 2019

作者其他论文 更多>>