Reproducibility of Aortic Pulsatility Measurements From ECGGated Abdominal CTA in Patients with Abdominal Aortic Aneurysms
文献类型: 会议论文
第一作者: Armando Manduca
作者: Armando Manduca 1 ; Joel G. Fletcher 2 ; Robert J. Wentz 1 ; Raymond C. Shields 3 ; Terri J. Vrtiska 2 ; Hassan Siddiki 2 ; Theresa Nielson 2 ;
作者机构: 1.Biomathematics Resource, Mayo Clinic College of Medicine 200 1~(st) St. S.W., Rochester, MN, USA 55905
2.Dept. of Diagnostic Radiology, Mayo Clinic College of Medicine 200 1~(st) St. S.W., Rochester, MN, USA 55905
3.Dept. of Cardiovascular Diseases, Mayo Clinic College of Medicine 200 1~(st) St. S.W., Rochester, MN, USA 55905
关键词: Reproducibility;Measurements;CTA
会议名称: SPIE Conference on Medical Imaging 2009
主办单位:
页码: 72620L:1-72620L:8
摘要: Purpose: ECG-gated abdominal CT angiography with reconstruction of multiple, temporally overlapping CT angiography datasets has been proposed for measuring aortic pulsatility. The purpose of this work is to develop algorithms to segment the aorta from surrounding structures from CTA datasets across cardiac phases, calculate registered centerlines and measurements of regional aortic pulsatility in patients with AAA, and to assess the reproducibility of these measurements. Methods: ECG-gated CTA was performed with a temporal resolution of 165 ms, reconstructed to 1 mm slices ranging at 14 cardiac phase points. Data sets were obtained from 17 patients on which two such scans were performed 6 to 12 months apart. Automated segmentation, centerline generation, and registration of centerlines between phases was performed, followed by calculation of cross-sectional areas and regional and local pulsatility. Results: Pulsatility calculations for the supraceliac region were very reproducible between earlier and later scans of the same patient, with average differences less than 1% for pulsatility values ranging from 2% to 13%. Local radial pulsatilities were also reproducible to within -1%. Aneurysm volume changes between scans can also be quantified. Conclusion: Automated segmentation, centerline generation, and registration of temporally resolved CTA datasets permit measurements of regional changes in cross-sectional area over the course of the cardiac cycle (i.e., regional aortic pulsatility). These measurements are reproducible between scans 6-12 months apart, with differences in aortic areas reflecting both aneurysm remodeling and changes in blood pressure. Regional pulsatilities ranged from 2 to 13% but were reproducible at the 1% level.
分类号: N52
- 相关文献
[1]一种提取悬铃叶苎麻(Bt.ricuspis (Hance) Marino)花序RNA的方法. 程超华,赵立宁,臧巩固,李育君,邱财生. 2006
[2]一种提取悬铃叶苎麻(Bt.ricuspis(Hance)Marino)花序RNA的方法. 程超华,赵立宁,臧巩固,李育君,邱财生. 2006
[3]Reproduction and In-Depth Evaluation of Genome-Wide Association Studies and Genome-Wide Meta-analyses Using Summary Statistics. Niu, Yao-Fang,Guo, Long-Biao,Ye, Chengyin,Zheng, Hou-Feng,He, Ji,Han, Fang,Zheng, Hou-Feng,Chen, Guo-Bo. 2017
[4]Comparative Analysis of Tagging and Feature-Tracking Cardiac MRI Techniques for the Evaluation of Cardiac Deformation. Pascual Tejero-Cervera,Jose V. Monmeneu,Alicia Maceira,Irene Del-Canto,Silvia Ruiz-Espana,Vicente Bodi,Maria P. Lopez-Lereu,Jose Manuel Santabarbara,David Moratal. 2020
作者其他论文 更多>>
-
Automatic Segmentation and Co-Registration of Gated CT Angiography Datasets: Measuring Abdominal Aortic Pulsatility
作者:Robert Wentz;Armando Manduca;JG Fletcher;Hassan Siddiki;Raymond C. Shields;Terri Vrtiska;Garrett Spencer;Andrew N. Primak;Jie Zhang;Theresa Nielson;Cynthia McCollough;Lifeng Yu
关键词:
-
Electronic Stool Subtraction Using Quadratic Regression, Morphological Operations, and Distance Transforms
作者:Michael Carston;Armando Manduca;C. Daniel Johnson;SPIE-The International Society for Optical Engineering
关键词:colon;cancer;colonography;colonoscopy;CT;electronic stool subtraction;stool tagging;colon cleansing
-
Automatic Segmentation and Co-Registration of Gated CT Angiography Datasets: Measuring Abdominal Aortic Pulsatility
作者:Robert Wentz;Armando Manduca;JG Fletcher;Hassan Siddiki;Raymond C. Shields;Terri Vrtiska;Garrett Spencer;Andrew N. Primak;Jie Zhang;Theresa Nielson;Cynthia McCollough;Lifeng Yu;SPIE-The International Society for Optical Engineering
关键词:
-
CT colonography of the unprepared colon: An evaluation of electronic stool subtraction
作者:Michael J. Carston;Robert J. Wentz;Armando Manduca;C. Daniel Johnson
关键词:colon;cancer;colonography;colonoscopy;CT;electronic stool subtraction;stool tagging;colon cleansing
-
Improved inversion of MR elastography images by spatio-temporal directional filtering
作者:Armando Manduca;David S. Lake;Richard L. Ehman;SPIE―The International Society for Optical Engineering
关键词:elasticity;elastography;shear modulus;tissue characterization;inversion algorithms;digital filters;wave propagation;shear wave
-
Correction of translation induced artifacts in wrist MRI scans using orthogonal acquisitions
作者:Edward Brian Welch;Armando Manduca
关键词:MRI;motion correction;motion artifacts;orthogonal acquisitions


