您好,欢迎访问中国农业科学院 机构知识库!

Comparative micro computed tomography study of a vertebral body

文献类型: 会议论文

第一作者: Susanne Drews

作者: Susanne Drews 1 ; Felix Beckmann 2 ; Julia Herzen 2 ; Oliver Brunke 3 ; Phil Salmon 4 ; Sebastian Friess 5 ; Andres Laib 6 ; Bruno Koller 6 ; Thomas Hemberger 3 ; Magdalena Muller-Gerbl 1 ; Bert Muller 7 ;

作者机构: 1.Institute of Anatomy, University of Basel, 4056 Basel, SWITZERLAND

2.GKSS-Research Center, 21502 Geesthacht, GERMANY

3.phoenix|x-ray Systems + Services GmbH, 31515 Wunstorf, GERMANY

4.Skyscan, 2550 Kontich, BELGIUM

5.Gloor Instruments AG, 8610 Uster, SWITZERLAND

6.Scanco Medical AG, 8306 Brutisellen, SWITZERLAND

7.Biomaterials Science Center, University of Basel, 4031 Basel, SWITZERLAND

关键词: spine;bone-cartilage interface;synchrotron radiation;micro computed tomography

会议名称: SPIE Conference on Developments in X-ray Tomography

主办单位:

页码: 70780C:1-70780C:14

摘要: Investigations of bony tissues are often performed using micro computed tomography based on X-rays, since the calcium distribution leads to superior contrast. Osteoporotic bone, for example, can be well compared with healthy one with respect to density and morphology. Degenerative and rheumatoid diseases usually start, however, at the bone-cartilageinterface, which is hardly accessible. The direct influence on the bone itself becomes only visible at later stage. For the development of suitable therapies against degenerative cartilage damages the exact three-dimensional description of the bone-cartilage interface is vital, as demonstrated for transplanted cartilage-cells or bone-cartilage-constructs in animal models. So far, the morphological characterization was restricted to magnetic resonance imaging (MRI) with poor spatial resolution or to time-consuming histological sectioning with appropriate spatial resolution only in two rather arbitrarily chosen directions. Therefore, one should develop μCT to extract the features of low absorbing cartilage. The morphology and the volume of the inter-vertebral cartilage disc of lumbar motion segments have been determined for one PMMA embedded specimen. Tomograms were recorded using nanotom (Phoenix|x-ray, Wunstorf, Germany), μCT 35~( TM) (Scanco Medical, Brutisellen, Switzerland), 1172~(TM) and 1174~(TM) (both Skyscan, Kontich, Belgium), as well as using the SRμCT at HASYLAB/DESY. Conventional and SRμCT can provide the morphology and the volume of cartilage between bones. Increasing the acquisition time, the signal-to-noise ratio becomes better and better but the prominent artifacts in conventional μCT as the result of inhomogeneously distributed bony tissue prevents the exact segmentation of cartilage. SRμCT allows segmenting the cartilage but requires long periods of expensive beamtime to obtain reasonable contrast.

分类号: N52

  • 相关文献

[1]The microstructure of mandibular bone graftsand three-dimensional cell clusters. Sarper Gurel,Corinne Unold,Hans Deyhle,Georg Schulz,Sebastian Kuhl,Belma Saldamli,Jutta Tubel,Rainer Burgkart,Felix Beckmann,Bert Muller. 2010

[2]3D analysis of bone formation around titanium implants using micro-computed tomography (μCT). Ricardo Bernhardt,Dieter Scharnweber,Bert Müller,Felix Beckmann,Jürgen Goebbels,John Jansen,Henning Schliephake,Hartmut Worch. 2006

[3]3D analysis of bone formation around titanium implants using micro computed tomography (μCT). Ricardo Bernhardt,Dieter Scharnweber,Bert Mueller,Felix Beckmann,Juergen Goebbels,John Jansen,Henning Schliephake,Hartmut Worch,SPIE-The International Society for Optical Engineering. 2006

[4]Internal structures of scaffold-free 3D cell cultures visualized by synchrotron radiation-based micro computed tomography. Belma Saldamli,Julia Herzen,Felix Beckmann,Jutta Tubel,Johannes Schauwecker,Rainer Burgkart,Philipp Jurgens,Hans-Florian Zeilhofer,Robert Sader,Bert Muller. 2008

[5]Detection of Degenerative Osteophytes of the Spine on PET/CT Using Region-Based Convolutional Neural Networks. Yinong Wang,Jianhua Yao,Joseph E. Burns,Jiamin Liu,Ronald M. Summers. 2017

[6]VERTEBRAL TRABECULAR TISSUE MODULUS OF GOAT AS COMPARED TO HUMAN USING ULTRASONIC AND MICROCT APPROACH. Jeremy CM Teo,Andy ZC Png,Swee Hin Teoh. 2004

[7]Automatic Segmentation of the Spine by Means of a Probabilistic Atlas With a Special Focus on Ribs Suppression. Preliminary Results. Ruiz-Espana, Silvia,Domingo, Juan,Diaz-Parra, Antonio,Dura, Esther,D'Ocon-Alcaniz, Vctor,Arana, Estanislao,Moratal, David. 2015

[8]Characterization of mechano-sensitive nano-containers for targeted vasodilation. Marzia Buscema,Hans Deyhle,Thomas Pfohl,Simone E. Hieber,Andreas Zumbuehl,Bert Müller. 2016

[9]Evaluating tooth restorations: Micro computed tomography inpractical training for students in dentistry. Hans Deyhle,Fredy Schmidli,Gabriel Krastl,Bert Muller. 2010

[10]Determination of strain fields in porous shape memory alloys usingmicro computed tomography. Therese Bormann,Sebastian Friess,Michael de Wild,Ralf Schumacher,Georg Schulz,Bert Muller. 2010

[11]High-resolution tomographic imaging of microvessels. Bert Muller,Sabrina Lang,Marco Dominietto,Markus Rudin,Georg Schulz,Hans De yhle,Marco Germann,Franz Pfeiffer,Christian David,Timm Weitkamp. 2008

[12]Morphology of urethral tissues. Bert Muller,Georg Schulz,Julia Herzen,Shpend Mushkolaj,Therese Bormann,Felix Beckmann,Klaus Puschel. 2010

[13]Angiofil: a novel radio-contrast agent for post-mortem microangiography. Silke Grabherr,Marco Dominietto,Lisa Yu,Valentin Djonov,Bert Muller,Sebastian Friess. 2008

[14]Comparative study of desktop- and synchrotron radiation-based micro computed tomography analyzing cell-seeded scaffolds in tissue engineering of bone. Adam Papadimitropoulos,Sebastian Friess,Felix Beckmann,Phil Salmon,Stefania Riboldi,Dietmar Hutmacher,Ivan Martin,Bert Muller. 2008

[15]High density resolution in synchrotron-radiation-based attenuation-contrast microtomography. Felix Beckmann,Julia Herzen,Astrid Haibel,Bert Muller,Andreas Schreyer. 2008

[16]Recent developments in X-ray Talbot interferometry at ESRF-ID19. Timm Weitkamp,Irene Zanette,Christian David,Jose Baruchel,Martin Bech,Pascal Bernard,Hans Deyhle,Tilman Donath,Johannes Kenntner,Sabrina Lang,Jurgen Mohr,Bert Muller,Franz Pfeiffer,Elena Reznikova,Simon Rutishauser,Georg Schulz,Arne Tapfer,Jean-Paul Valade. 2010

[17]Non-rigid registration to determine strain fields during mouse brain fixation and embedding. Bert Mueller,Christine Tanner,Griffin Rodgers,Georg Schulz,Willy Kuo,Mario Scheel,Vartan Kurtcuoglu,Timm Weitkamp. 2021

[18]X-ray grating interferometer for imaging at asecond-generation synchrotron radiation source. Julia Herzen,Felix Beckmann,Tilman Donath,Malte Ogurreck,Christian David,Franz Pfeiffer,Jurgen Mohr,Elena Reznikova,Stefan Riekehr,Astrid Haibel,GeorgSchulz,Bert Muller,Andreas Schreyer. 2010

[19]Mosaic microtomography of a full mouse brain with sub-micron pixel size. Griffin Rodgers,Christine Tanner,Georg Schulz,Timm Weitkamp,Mario Scheel,Marta Girona Alarcon,Vartan Kurtcuoglu,Bert Mueller. 2022

[20]Three-dimensional imaging of porcine joint tissues down to the subcellular level. Georg Schulz,Andrea Barbero,Francine Wolf,Griffin Rodgers,Christine Tanner,Timm Weitkamp,Marcus Mumme,Marta Morawska,Daniel Beer,Bert Mueller. 2022

作者其他论文 更多>>