您好,欢迎访问中国农业科学院 机构知识库!

Comparative study of desktop- and synchrotron radiation-based micro computed tomography analyzing cell-seeded scaffolds in tissue engineering of bone

文献类型: 会议论文

第一作者: Adam Papadimitropoulos

作者: Adam Papadimitropoulos 1 ; Sebastian Friess 2 ; Felix Beckmann 3 ; Phil Salmon 4 ; Stefania Riboldi 1 ; Dietmar Hutmacher 5 ; Ivan Martin 1 ; Bert Muller 6 ;

作者机构: 1.University Hospital Basel, Basel, Switzerland

2.Gloor Instruments AG, Switzerland

3.GKSS Research Center, Geesthacht, Germany

4.Sky Scan NV , Belgium

5.Queensland University of Technology, Australia

6.Biomaterials Science Center, University of Basel, Switzerland

关键词: micro computed tomography;scaffold;tissue engineering;morphometry;porosity;rigid registration

会议名称: SPIE Conference on Developments in X-ray Tomography

主办单位:

页码: 70780T:1-70780T:11

摘要: In the field of tissue engineering, micro computed tomography (μCT) should allow non-destructively assessing the extracellular matrix deposited by cells within porous scaffolds in-vitro. While synchrotron radiation-based μCT combines micrometer resolution with a high signal-to-noise ratio (contrast), recent advances in desktop μCT devices have achieved comparable results with benefits in availability and user-friendliness. In this study we compare the performance of the commercially available, entry-level desktop device 1174 (SkyScan, Belgium) with the μCT at HASYLAB (DESY, Hamburg, Germany) by characterizing porous interconnected 3D scaffolds and monitoring the development of engineered human bone constructs upon culture in such an environment. Expansion of human osteogenic cells has been performed with the use of perfusion bioreactors and 3D scaffolds, serving as cell carriers. Constructs based on low X-ray absorbing, rapid-prototyped fibrous scaffolds were analyzed with a nominal spatial resolution of better than 5 μm. Direct 3D image analysis allowed for the accurate quantification of the scaffold morphometry parameters, where both μCT techniques yielded comparable results. However, due to the monochromatic nature of X-rays available at the synchrotron radiation source, drastically reduced beam hardening effects and higher density resolution (higher dynamic range) has been obtained at HASYLAB. Studies in this direction could be useful to highlight the mechanisms that are involved in bone-like tissue growth and to further understand how it can be affected by the choice of cell type, 3D culture environment and scaffold type and architecture.

分类号: N52

  • 相关文献

[1]Elastic Ceramic-Polymer Scaffold with Interconnected Pore Structure: Preparation and In Vitro Reactivity. Minna Malin,Joni Korventausta,Ville Meretoja,Jukka Seppaelae. 2008

[2]Study on Tissue Engineering Scaffolds of Silk Fibroin-Chitosan/nano-Hydroxyapatite Composite. Guangwu WEN,Jing WANG,Muqin LI,Xiangcai MENG. 2007

[3]A Novel Collagen Sponge for Cartilage Tissue Engineering. Guoping Chen,Daisuke Akahane,Naoki Kawazoe,Yoshio Shirasaki,Junzo Tanaka,Katsuyuki Yamamoto,Tateishi Tateishi. 2007

[4]High Resolution X-ray Imaging of Dynamic Solute Transport in Cyclically Deformed Porous Tissue Scaffolds. Jorn Op Den Buijs,Kee-Won Lee,Steven M. Jorgensen,Shanfeng Wang,Michael J. Yaszemski,Erik L. Ritman. 2008

[5]Fabrication of Macroporous Scaffold Using Calcium Phosphate Glass for Bone Regeneration. T. Yoshikawa1,Y. Ueda1rl Ohmura,Y. Sen1,J. lida,M. Koizumi,K. Kawate. 2003

[6]Evaluation of RGD-grafted Porous PLLA Scaffold for Chondrogenic Differentiation of Stem Cells. Hyun Jung Jung,Kwideok Park,Kyoung Jin Cho,Kwang-Duk Ann,Dong-June Ann,Dong Keun Han. 2007

[7]芝麻基因组解析与利用. 王林海. 2014

[8]Enhanced Proliferation and Osteogenic Differentiation of Mesenchymal Stem Cells on Graphene Oxide-Incorporated Electrospun Poly(lactic-co-glycolic acid) Nanofibrous Mats. Luo, Yu,Shen, He,Cao, Yuhua,Huang, Jie,Zhang, Mengxin,Dai, Jianwu,Zhang, Zhijun,Luo, Yu,Shi, Xiangyang,Fang, Yongxiang,Dai, Jianwu,Fang, Yongxiang. 2015

[9]Effect of different tillage systems on aggregate structure and inner distribution of organic carbon. Gao, Lili,Becker, Eleonore,Degre, Aurore,Gao, Lili,Liang, Guopeng,Houssou, Assa Albert,Wu, Huijun,Wu, Xueping,Cai, Dianxiong.

[10]Computed tomography to quantify tooth abrasion. Lukas Kofmehl,Georg Schulz,Hans Deyhle,Andreas Filippi,Gerhard Hotz,DorotheaBerndt-Dagassan,Simon Kramis,Felix Beckmann,Bert Muller. 2010

[11]Improvement of the Mechanical Properties of Calcium Phosphate Bone Substitutes by Polycaprolactone Infiltration. Marion Quiquerez,Marianna Peroglio,Laurent Gremillard,Jerome Chevalier,Laurent Chazeau,Catherine Gauthier,Thierry Hamaide,Aurelien Bignon. 2008

[12]ATLANTIK Genta, A New Concept Of Gentamicin Loaded HAP/TCP Bone Substitute For Prophylactic Action - In Vitro Releasing Mechanisms Study. A. Bignon,F. Laurent,J. Goldnadel,J. Chevalier,G. Fantozzi,E. Viguier,T. Roger,G. Boivin,D. Hartmann. 2008

[13]Development of in situ-formed interconnected porous scaffolds with low porosity. Yulin Li,Masanori Kikuchi. 2008

[14]Accelerating the Setting of Portland Cement Based Dental Materials using Calcium Sulphates. J. L. O'Beirne,R. M. Shelton,P. J. Lumley,M. P. Hofmann. 2008

[15]Fabrication of Low Temperature Hydroxyapatite Foams. A. Almirall,G. Larrecq,JA. Delgado,S. Martinez,M.P Ginebra,J.A. Planeil. 2003

[16]Effect of Mechanical Mixing and Powder to Liquid Ratio on the Strength and Reliability of a Brushite Bone Cement. S. Mahmood,W.M. Palin,U. Gbureck,O. Addison,M.P. Hofmann. 2008

[17]Shape Memory Scaffold with a Tunable Recovery Temperature for Filling Critical-Size Bone Defects. R.M. Baker,J.H. Henderson,P.T. Mather. 2013

[18]Characterization of mechano-sensitive nano-containers for targeted vasodilation. Marzia Buscema,Hans Deyhle,Thomas Pfohl,Simone E. Hieber,Andreas Zumbuehl,Bert Müller. 2016

[19]Evaluating tooth restorations: Micro computed tomography inpractical training for students in dentistry. Hans Deyhle,Fredy Schmidli,Gabriel Krastl,Bert Muller. 2010

[20]Determination of strain fields in porous shape memory alloys usingmicro computed tomography. Therese Bormann,Sebastian Friess,Michael de Wild,Ralf Schumacher,Georg Schulz,Bert Muller. 2010

作者其他论文 更多>>