An ultrasensitive lateral flow immunoassay platform for foodborne biotoxins and pathogenic bacteria based on carbon-dots embedded mesoporous silicon nanoparticles fluorescent reporter probes

文献类型: 外文期刊

第一作者: Wang, Yuhui

作者: Wang, Yuhui;Deng, Chen;Qian, Sihua;Fu, Pan;Zheng, Jianping;Deng, Chen;Zhou, Hualan;Li, Hui

作者机构:

关键词: Carbon-Dots; Mesoporous silicon nanoparticles; Fluorescence probe; Lateral flow immunoassay; Foodborne pollutants

期刊名称:FOOD CHEMISTRY ( 影响因子:9.231; 五年影响因子:8.795 )

ISSN: 0308-8146

年卷期: 2023 年 399 卷

页码:

收录情况: SCI

摘要: Lateral flow immunoassays (LFIAs) are routine methods for rapid foodborne pollutants screening, with detection limits that are closely associated with the label probes used. The exploitation of high performance and robust probe is highly desirable, and remains a great challenge. Herein, we reported an emerging fluorescent nanobeads i.e. carbon-dots (CD) covalently incorporated mesoporous silicon nanoparticles (CD-MSNs) for LFIAs. CD-MSNs revealed brighter fluorescence, larger particle size and more modification sites in comparison with those of single CD. After bio-functionalisation, CD-MSNs probes were introduced to construct LFIA test strips, and designed for ultrasensitive detection of aflatoxin B1 (AFB1) and Staphylococcus aureus (S. aureus), two representative foodborne pollutants, based on the competitive and sandwich models, respectively. Very competitive quantitative detection limits i.e. 0.05 ng/mL and 10(2) cfu/mL were correspondingly obtained. Additionally, the test strips were successfully applied to rapidly and accurately screen AFB1 and S. aureus in food samples, highlighting their practicality.